ResMed AirSense 11 Auto CPAP Machine – EU Model

SKU39140

The ResMed AirSense 11 Auto CPAP Machine is designed to increase your therapy success, featuring an easy-to-use touch screen and two built-in auto-algorithms. The sleek design and advanced event detection can also be combined with an optional humidifier and heated tube to enhance your comfort.

Please note: This is an EU model with no English menu; however, a UK plug is included, and there is no import tax. The package includes an EU manual only, but you can download the English manual here. myAir does not work in the UK with this model, and there is no release date at this time. The AirSense 10 remains the latest UK model.

This product is eligible for VAT relief

VAT on this product will be charged at 0% if VAT relief is claimed at the final stage of the checkout process. Please be aware VAT will show at 20% until that point. Full details can be found here and at the checkout.

£649.00with VAT Relief

In Stock

Add Humidification for Enhanced Comfort

  • ResMed AirSense 11 Auto CPAP Machine | CPAP.co.uk
  • AirSense 11 ClimateLineAir Heated Tube | CPAP.co.uk
  • AirSense 11 HumidAir Humidifier Water Chamber | CPAP.co.uk
Total Price: Original price was: £783.98.Current price is: £749.00.
Save £34.98 when bought together

ResMed AirSense 11 Auto CPAP Machine

The AirSense 11 Auto CPAP machine is the newest generation of the popular ResMed AirSense series. The AirSense 11 automatically adjusts (increases and decreases) your pressure settings and features an AutoRamp to make falling asleep easy. Featuring enhanced digital health technology and two auto-algorithms for more personalised therapy.

The sleek and compact design of the ResMed AirSense 11 design makes travelling with your machine more manageable. Therapy is simple for everyone with the user-friendly start-stop function and easy navigation via the smart touch screen.

 

AirSense 11 Features and Advantages

Dual Auto Algorithms: The AirSense 11 offers two adaptive therapy modes—AutoSet and AutoSet for Her—both conveniently integrated into one device. The AutoSet for Her mode is tailored to women’s unique Obstructive Sleep Apnoea patterns, with gentler pressure adjustments for a more personalised therapy experience.

Enhanced Touch Screen: The AirSense 11 maintains the intuitive design of its predecessor, the AirSense 10 while introducing a larger touch screen with auto-dimming lights. This reduces nighttime disruptions and enhances usability.

Automatic Ramp: The Auto Ramp feature starts therapy with a lower pressure, gradually increasing to the prescribed level once the user is asleep. This functionality particularly benefits those new to CPAP therapy, helping them adjust comfortably.

Event Detection: The device distinguishes between Obstructive Sleep Apnoea and central apnoea events, offering a detailed analysis of therapy performance. This ensures accurate tracking and better management of your sleep health.

Easy Start/Stop Control: The AirSense 11 features a prominent button for quickly starting or stopping therapy.

Smart-Start Technology: With the Smart-Start function, the machine begins therapy automatically when the mask is in place and breathing is detected.

 

Optional HumidAir Humidification System

The device seamlessly integrates with the optional AirSense 11 HumidAir Humidifier and AirSense 11 ClimateLineAir Heated Tube. These add-ons reduce dryness and discomfort caused by cold air but are exclusively compatible with the AirSense 11.

HumidAir Humidifier: This optional humidifier warms and moistens the airflow for enhanced comfort. Its removable water tub simplifies cleaning and maintenance.

ClimateLineAir Heated Tubing: While the device comes with a standard 15mm tube, upgrading to the AirSense 11 ClimateLineAir Heated Tube when using the HumidAir Humidifier improves humidification and prevents the air from cooling as it flows through the hose.

 

What’s Included with the AirSense 11

  • ResMed AirSense 11 CPAP Machine
  • Standard slimline tube (15mm)
  • Two CPAP filters
  • Travel case
  • Power adapter
  • User manual

Suggested Replacement Timeline

  • Tubing: Replace every three months or sooner if needed.
  • Filters: Replace disposable filters monthly; reusable filters every three months or as required.
  • Water Chamber: Replace every six to twelve months or if signs of wear (cracks, discolouration) appear.
  • Mask: Replace components every 3–6 months, depending on maintenance.

Important Information: This is an ‘automatic’ CPAP machine, which automatically adjusts the pressure for the user, although it can also be set with specific pressure settings if required. If you have not yet had Sleep Apnoea identified or do not have any written confirmation of Sleep Apnoea, or prior CPAP usage that you can send us, please consider our quick In-Home Sleep Test. If you have any questions, please contact us via email or call us on 0800 024 8050.

Additional information

Warranty

Two-years – applies only to the CPAP device itself. Excludes accessories such as the power supply, filters and tubing.

Condition

New

Weight (CPAP unit only)

1.13 kg

Tube Warranty

90 Days

Sound Level (dBa)

27dBA

Power Cord Length

1.8m

Heated Hose

Optional (sold separately)

Exhalation Relief

Yes

Ramp Mode

Yes

DC Capable

Yes (DC cable not included)

Battery Option

No

CE/UKCA Certified

Yes

Manufacturer

ResMed

Consumables warranty

3 Months

Dimensions (CPAP unit only)

22 x 13 x 9 cm

Humidification

Optional (sold separately)

Tube type included

15mm slimline tube

Electrical Requirements

1.0 – 1.5A, 100 – 240V / 50 – 60Hz

Mask Compatibility

Universal

What's in the box

Machine, 15mm slimline tube, 65W power supply, travel bag, user guide, x2 filters

Pressure range

4-20cmH2O

Pressure mode(s)

Automatic or Fixed

Dimensions (with humidifier attached)

25 x 13 x 9 cm

What's the difference between the AirSense 10 and the AirSense 11?

ResMed has enhanced the most popular aspects of the AirSense 10, refining them further in the updated model. The AirSense 11 boasts a more compact and lightweight design, making it easier to take on the go.

Equipped with updated software and an improved colour touchscreen, the AirSense 11 is designed to be more energy-efficient than its predecessor. Instead of operating with a 90-watt power unit like the AirSense 10, the new model functions on a 65-watt unit, reducing power consumption.

In the AirSense 10, two separate machines were required to accommodate different algorithms. With the AirSense 11, the “For Her” feature has been seamlessly integrated into a single device, simplifying usage.

Can I use my ResMed AirSense 11 without a humidifier?

Yes, you can choose not to use a humidifier with the AirSense 11. The machine does not include the humidifier; this is an optional extra.

If you have the humidifier connected but you prefer not to use it, you can easily disable the humidifier. Navigate to your settings, locate the relevant options, and turn off the humidifier feature. Afterwards, you can detach the water chamber and replace it with a side cover.

Does the AirSense 11 turn off automatically?

No, it does not.

How loud is the ResMed AirSense 11?

The AirSense 11 CPAP operates at a sound level of just 27 decibels, ensuring a quiet experience. Designed with ResMed’s EasyBreathe motor, it promotes a calm and restful environment for both the user and their sleep partner.

What does the snowflake mean on AirSense 11?

The snowflake icon appears when your humidifier is cooling down.

How often do you change the filter in ResMed AirSense 11?

Disposable filters should be replaced every 30 days, while reusable filters can last up to three months—though they may need replacing sooner if there is visible buildup. To remove the air filter, access the back of the device and pull down the tab to release it.

Am I allowed to bring my AirSense 11 on a plane?

Yes, the device is FAA-approved.

Since CPAP machines are considered medical equipment, they do not count toward your carry-on allowance when flying. Ensure to activate aeroplane mode on your device and avoid filling the water chamber before the flight to prevent leaks or potential damage.